2022 Caterpillar Automatic Transfer Switch ATC Breaker / Contactor ATC Power Breaker & Case Switch Automatic

2022 Caterpillar Automatic Transfer Switch ATC Breaker / Contactor ATC Power Breaker & Case Switch Automatic

Swipe to View More

  • Year 2022
  • Make Caterpillar
  • Model Automatic Transfer Switch ATC Breaker / Contactor
2022 Caterpillar Automatic Transfer Switch ATC Breaker / Contactor ATC Power Breaker & Case Switch Automatic

2022 Caterpillar Automatic Transfer Switch ATC Breaker / Contactor ATC Power Breaker & Case Switch Automatic

2022 Caterpillar Automatic Transfer Switch ATC Breaker / Contactor ATC Power Breaker & Case Switch Automatic

Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open transition power case switch-based Automatic Transfer Switch (ATS) will provide fully functioning transfer in applications where a momentary loss of power is acceptable on retransfer from emergency to normal power supply. The Cat power case switch-based ATS also permits periodic testing of the emergency source without interrupting power to the loads and are available from 200 to 5000.

ATC-900 MICROPROCESSOR-BASED CONTROLLER AND POWER BREAKER

Fastest switching times available (<3 cycles) Full 60-cycle short time withstand capabilityALL CONTROLS RELAYS AND INDUSTRIAL GRADE RELAYS

Lugs are 90" rated and all control wire is #16 AWG, type XLPE with a 125" temperature rating.

DURABLE POWDER-COATED STEEL NEMA 1, 3R OR 12 ENCLOSURES WITH THREE DOOR HINGES.

The hinges have removable hinge pins to facilitate door removal and are supplied with pad-lockable latches

Features may include:
  • atc-800 Microprocessor-based Controller
  • voltage And Frequency Sensing
  • fastest Switching Times Available (<3 Cycles)
  • full 60-cycle Short Time Withstand Capability
  • multiple Field Programmable Time Delays
  • switch Position Indication
  • source Availability Indication
  • safe Manual Transfer Under Load
  • source 1 And 2 Auxiliary Contacts
  • programmable Plant Exerciser
  • system Test Pushbutton
  • load Shed From Emergency
  • mimic Diagram
  • true Rms Three Phase Voltage Sensing On Source 1, Source 2 And Load
  • frequency Sensing On Source 1 And Source 2
  • mechanical (Cable) And Electrical Interlocking To Prevent Paralleling Of Sources
  • safe Manual Operation Under Full Load With Permanently Affixed Operating Handle
  • ambient Temperature Range: -40°c To 40°c (-40°f To 104°f)
  • operating Temperature Range: -20°c To 70°c (-4°f To 158°f)
  • operating Humidity: Up To 90%
  • relative Humidity (Non-condensing)
  • source Paralleling Duration Is Limited To 100 Msec Or Less
  • source Availability Indication

Electric

Electrical Rating Range: 200 to 5000A | Control Power: Fixed Mount 200-3200A 2, 3, or 4 Pole Drawout 200-5000A 2-, 3-, 4-pole | System Voltage Application: 120 - 600 Vac, 50/60 Hz | Withstand: 100,000 amps withstand/closing/ interrupting at 600 Vac

Operational

Operating Conditions Time Withstand: 85,000 for 30 cycles

Features

Features Transfer Type: Open Transition | Switch Type: Power Breaker | Applicable Testing: CSA C22.2 No. 178 certified IBC 2006, CBC 2007 and OSHPD

Product Photography